CE 7.17: Inadequate Air Supply
Article type: Common ElementAir supply systems shall provide the air flow required by the design.
-
CE 7.18: Glycol Levels Are Below Specified Percentages/Levels
Article type: Common ElementPerformance/Condition: Glycol levels/percentage shall meet with the requirements of the design.
-
Common Element 7.19: Inadequate Cooling
Article type: Common ElementIf a cooling system is provided, it shall be capable of maintaining indoor air temperature at the temperature specified in the design for the geographic location of the building. Not all cooling systems are intended to run all year, so this requirement only applies to the portion of the year that the design indicates is to be provided with cooling.
-
CE 7.2: Damage Caused By Condensation On Piping Systems
Article type: Common ElementPiping system shall be installed to prevent damage due to condensation.
-
CE 7.20: Flow Velocity Or Imbalance In Domestic Water Systems
Article type: Common ElementWater flow velocity and system balance in domestic water pipes should meet the requirements of the Ontario Building Code and the design.
-
CE 7.21: Missing Clean-Outs
Article type: Common ElementClean-outs shall be installed to facilitate maintenance, as required by the Ontario Building Code and the design. -
CE 7.3: Plumbing Or Sprinkler Pipes Freeze And/Or Burst
Article type: Common ElementPlumbing and sprinkler pipes exposed to freezing temperatures should be protected so the fluid inside does not freeze.
-
CE 7.4: Sanitary And/Or Drainage Systems Don't Drain Properly
Article type: Common ElementSanitary and storm drainage systems shall drain waste products to a public sewer or private sewer disposal system as per the design.
-
CE 7.5: Faucet Or Fixture Leaking
Article type: Common ElementFaucets or plumbing fixtures shall not leak, drip or run when fully closed or shut off.
-
CE 7.6: Exhaust System Terminates In Attic, Crawl or Conaled Spa
Article type: Common ElementExhaust systems shall be ducted in such a fashion that they do not cause condensation in attics, crawl spaces or other concealed spaces. -
CE 7.7: Noisy Water Supply Pipes
Article type: Common ElementWater supply pipes shall be installed to minimize noise caused by water hammer or vibration/pipe movement.
-
CE 7.8: Defective Plumbing Fixtures, Appliances Or Trim Fittings
Article type: Common ElementPlumbing fixtures, appliances or trim fittings shall be free of both visual and performance defects.
-
CE 8.1: Receptacles/Switch Cover Plate Is Not Flush With The Wall
Article type: Common ElementElectrical receptacles/switches shall be installed so that the cover plate sits generally flush with the adjacent wall surface and square to surrounding finishes.
-
CE 8.2: Missing Cover Plate On Electrical Boxes
Article type: Common ElementElectrical cover plates shall be installed. -
CE 8.3: Electrical Equipment Missing Labels
Article type: Common ElementElectrical panels and circuits must be clearly labeled.