FH 3.16: Exterior Door Swings Open Or Closed By Itself

Performance

Exterior doors shall be installed sufficiently plumb and square so they do not swing by themselves due to the force of gravity alone

Warranty

One-Year - Work and Materials. · Alterations, deletions or additions by the homeowner are not covered by the statutory warranty.

Action

Exterior doors not meeting the acceptable performance shall be repaired.

Remarks

Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Doors will swing open or closed by the force of gravity if the hinges are not aligned plumb. See Also: 3.9 EXTERIOR DOOR IS WARPED 3.17 EXTERIOR DOOR IS CROOKED IN THE FRAME

Article number
3.16
Article type
Freehold
Warranty years
One Year
Article title
Exterior Door Swings Open Or Closed By Itself

FH 3.15: Plastic Moulding On Exterior Door Is Deformed

Performance

The plastic mouldings on exterior doors shall not deform when the door is installed in accordance with the manufacturer’s installation instructions.

Warranty

One-Year - Work and Materials. · Damage caused by improper maintenance or material, design or work supplied by the homeowner is not covered by the statutory warranty.

Action

Exterior doors not meeting the acceptable condition shall be repaired.

Remarks

Generally, exterior door manufacturers indicate storm doors are not to be installed over metal exterior doors. Heat buildup between a storm door and the exterior door can increase significantly, damaging any heat-susceptible parts such as plastic mouldings around a window insert or decorative surface-applied mouldings. The homeowner is also cautioned to follow manufacturer’s recommendations on maintenance and painting the mouldings a dark colour, with or without the use of a storm door; dark-coloured moulding is likely to deform and should be avoided.

Article number
3.15
Article type
Freehold
Warranty years
One Year
Article title
Plastic Moulding On Exterior Door Is Deformed

FH 3.14: Exterior Door Will Not Close Completely

Performance

Exterior doors shall close completely and latch securely.

Warranty

One-Year - Work and Materials

Action

Doors not meeting the acceptable performance shall be repaired.

Remarks

Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Slight pressure may be required during latching to compress the weatherstripping. Exterior doors can warp to some degree because of the difference in the temperature between inside and outside surfaces. See Also: 3.9 EXTERIOR DOOR IS WARPED 3.13 EXTERIOR DOOR STICKS 3.17 EXTERIOR DOOR IS CROOKED IN THE FRAME

Article number
3.14
Article type
Freehold
Warranty years
One Year
Article title
Exterior Door Will Not Close Completely

FH 3.13: Exterior Door Sticks

Performance

Exterior doors and their hardware shall be installed to operate with minimal binding taking into account the weatherstripping seal and seasonal periods of high humidity.

Warranty

One-Year - Work and Materials. · Alterations, deletions and additions made by the homeowner are not covered by the statutory warranty.

Action

Doors and hardware not meeting the acceptable performance shall be repaired.

Remarks

Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Exterior doors can warp to some degree because of the difference in the temperature between inside and outside surfaces. See Also: 3.9 EXTERIOR DOOR IS WARPED 3.14 EXTERIOR DOOR WILL NOT CLOSE COMPLETELY 3.17 EXTERIOR DOOR IS CROOKED IN THE FRAME

Article number
3.13
Article type
Freehold
Warranty years
One Year
Article title
Exterior Door Sticks

FH 3.11: Shrinkage Of Inserted Panels Shows Raw Wood Edges On Exterior Wood Doors

Performance

Wooden panels will shrink and expand because of temperature and/or humidity changes, and may expose unpainted surfaces; this is acceptable. However, gaps between the edge of an inserted panel and the rest of the door caused by shrinkage are not normal and not acceptable.

Warranty

One-Year - Work and Materials. · Normal shrinkage of materials caused by drying after construction is not covered by the statutory warranty.

Action

Doors not meeting the acceptable condition shall be repaired.

Remarks

None

Article number
3.11
Article type
Freehold
Warranty years
One Year
Article title
Shrinkage Of Inserted Panels Shows Raw Wood Edges On Exterior Wood Doors

FH 3.10: Exterior Metal Door is Dented

Performance

Exterior doors shall not be dented at the time of the PDI.

Warranty

One-Year - Work and Materials

Action

Dented exterior metal doors noted on the PDI Form shall be repaired. If not noted, the homeowner must establish that the damage was caused by the builder.

Remarks

Identify damaged doors on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Filling the dent is an acceptable repair (e.g. spot putty).

Article number
3.10
Article type
Freehold
Warranty years
One Year
Article title
Exterior Metal Door is Dented

FH 3.1: Wall is out of Plumb

Performance

Where the condition is visible from a normal viewing position, walls shall not be out of plumb more than 19 mm in 2,400 mm vertical measurement.

Warranty

One-Year - Work and Materials.

Action

Walls not meeting the acceptable condition shall be repaired.

Remarks

It is reasonable to expect minor variation from plumb. Fitment of furnishings is not considered to be the test for plumb. See Also: 3.2 WALL IS BOWED 9.3 GYPSUM WALLBOARD CORNERS ARE UNEVEN

Article number
3.1
Article type
Freehold
Warranty years
One Year
Article title
Wall is out of Plumb

CE 1.2: Leakage Through Buried Roof Slab - Not Exposed To Chlorides

Performance

Buried roof slabs shall be designed and constructed to prevent water penetration and leakage in accordance with the Ontario Building Code and the design.

Warranty

One-Year – Work and Materials. Two-Year - Building Envelope Water Penetration

Action

The waterproofing system, not meeting acceptable performance, shall be repaired.

Remarks

Repair shall prevent water from penetrating into the building Care must be taken to prevent damage to waterproof membrane during required maintenance activities to exposed surface above the buried roof. The Ontario Building Code references CSA S413, Item 4 which requires protection against leakage. Expansion joints shall be repaired to accommodate movement Exposed to chlorides refers to slabs which are exposed to de-icing chemicals. This typically applies to slabs located below driveways, parking, and walkways. Slabs located below sod or gardens would be considered “not exposed to chlorides”.

Article number
1.2
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Leakage Through Buried Roof Slab - Not Exposed To Chlorides

FH 2.6: Springiness, Bounce, Visible Sag When Loaded, Or Shaking Is Observed In The Floor

Performance
These conditions are acceptable when all structural members including beams and joists are sized, installed and fastened in accordance with the Building Code.
Warranty
One-Year - Work and Materials. Two-Year - Ontario Building Code Health & Safety Violations
Action
Floors not meeting the performance condition shall be repaired.
Remarks
Long-spanned floor joists will normally move more than short-spanned joists under design loads. The conditions can be assessed by determining the performance under loading conditions; measuring the length of the structural member and dividing by 360 will give the maximum deflection allowed. See Also: 2.2 FLOOR FRAMING DAMAGED BY WEATHER DURING CONSTRUCTION. 2.3 LOOSE SUBFLOOR
Article number
2.6
Article type
Freehold
Warranty years
One Year
Two Year
Article title
Springiness, Bounce, Visible Sag When Loaded, Or Shaking Is Observed In The Floor