Skip to main content

FH 9.10: Clear Interior Finishes have Deteriorated

Performance

Clear interior finishes shall not deteriorate to the extent that they expose the substrate beneath.

Warranty

One-Year - Work and Materials. · Damage resulting from normal wear and tear is excluded from the statutory warranty.

Action

Clear finishes not meeting the acceptable performance shall be repaired.

Remarks

Use of inappropriate household cleaners can sometimes contribute to discolouration and premature deterioration of finishes. See Also: 9.12 WALLCOVERING IS PEELING

Article number
9.10
Article type
Freehold
Warranty years
One Year
Article title
Clear Interior Finishes have Deteriorated

FH 9.5: Ceiling/Wall Joint Separation Commonly Referred to as "Truss Uplift"

Performance
Cracks resulting from normal shrinkage are acceptable; crack width in excess of 4 mm is not acceptable.
Warranty
One-Year - Work and Materials. · Cracks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty.
Action
Cracks in excess of the acceptable condition shall be repaired.
Remarks
Truss uplift may occur when outdoor temperatures are considerably colder than indoor temperatures. It can appear as a minor crack or a larger gap. Repairs should be deferred until such time as the truss returns to its original position. See Also: 9.4 CRACKS IN INTERIOR WALL AND CEILING SURFACES
Article number
9.5
Article type
Freehold
Warranty years
One Year
Article title
Ceiling/Wall Joint Separation Commonly Referred to as "Truss Uplift"

FH 9.2: Ceiling Texture is unevenly Applied

Performance
In a room or area, applied ceiling texture (i.e. stipple) shall appear generally uniform when viewed from a normal viewing position under normal lighting conditions.
Warranty
One-Year - Work and Materials
Action
Ceiling texture not meeting the acceptable condition shall be repaired.
Remarks
Minor variation in texture is normal with randomly applied finishing materials. See Also: 9.1 CEILING IS UNEVEN
Article number
9.2
Article type
Freehold
Warranty years
One Year
Article title
Ceiling Texture is unevenly Applied

FH 9.1: Ceiling is Uneven

Performance
Within a room or space, where an isolated bulge or area of waviness appears in the ceiling and is not a structural problem, the variation shall not be greater than 12mm above or below the specified plane.
Warranty
One-Year - Work and Materials.An isolated bulge or area of waviness in the ceiling caused by normal shrinkage of materials due to drying after construction is excluded from the statutory warranty.
Action
An isolated bulge or area of waviness in the ceiling greater than the acceptable performance shall be repaired.
Remarks
Even when installed according to the Ontario Building Code, it is not unusual to see an isolated bulge or area of waviness in drywalled ceilings due to joint finishing. These conditions may appear more severe at night when artificial lighting washes across the ceiling.An isolated bulge or area of waviness may also be caused by applying ceiling drywall over major structural components, such as beams, or possibly due to truss uplift. See section 9.5 Ceiling/Wall Joint Separation Commonly Referred to as "Truss Uplift".To measure this type of variation, refer to appendix A4: Measuring Variation from the Specified Plane using a Plane of Reference.NotesThis Article, as revised, applies to all conciliations after January 1, 2019.See also:9.2 CEILING TEXTURE IS UNEVENLY APPLIED9.3 GYPSUM WALLBOARD CORNERS ARE UNEVEN9.5 CEILING/WALL JOINT SEPARATION COMMONLY REFERRED TO AS “TRUSS UPLIFT”
Article number
9.1
Article type
Freehold
Warranty years
One Year
Article title
Ceiling is Uneven

FH 4.2: Wood or Hardboard or Panel-Type Siding - Joints not Tight

Performance

Wood or hardboard or panel-type siding shall be installed in accordance with the manufacturer’s specifications and the Building Code with gaps at joints to allow for expansion. Joints shall be suitably protected to prevent water penetration.

Warranty

One-Year - Work and Materials. Two-Year - Building Envelope Water Penetration · Normal shrinkage of materials caused by drying after construction is excluded from the statutory warranty. · Defects in materials, work or design supplied by the homeowner and damage resulting from improper maintenance are excluded from the statutory warranty.

Action

Wood or hardboard or panel-type siding joints that do not meet the acceptable condition shall be repaired.

Remarks

Siding that is intended to have paint and/or sealer requires regular inspection and maintenance to ensure continuity of the protective layer. Wood, hardboard or panel-type siding can be expected to expand and contract with fluctuations in outdoor temperature and humidity; gaps in joints may be required to prevent buckling. Caulking or attaching battens over the joints are ways to protect the joints from water penetration. Where rain screen principles are used in the cladding design, the sealing may be behind the surface of the cladding.

Article number
4.2
Article type
Freehold
Warranty years
One Year
Two Year
Article title
Wood or Hardboard or Panel-Type Siding - Joints not Tight

FH 4.1: Wood or Hardboard or Panel-Type Siding is Bowed or Wavy

Performance

Siding shall be installed to accommodate thermal movement and anticipated shrinkage of the structure to which it is attached. Siding shall be free from bows and waviness when installed in accordance with the manufacturer’s specifications. Where local distortion is caused by bowed framing, the deviation of the bow shall not exceed 20 mm from the specified plane.

Warranty

Two-Year - Cladding Detachment, Displacement or Deterioration. · Defects in materials, work or design supplied by the homeowner or damage resulting from improper maintenance are excluded from the statutory warranty.

Action

Bowed or wavy siding exceeding the acceptable condition shall be repaired.

Remarks

Siding that is intended to have paint and/or sealer requires regular inspection and maintenance to ensure continuity of the protective layer. Elevated moisture levels can cause wood or hardboard siding to bow. Varying lighting conditions can exaggerate minor variations in siding profile and texture. Minor waviness due to normal fluctuations in humidity is acceptable. See Also: 3.2 WALL IS BOWED

Article number
4.1
Article type
Freehold
Warranty years
Two Year
Article title
Wood or Hardboard or Panel-Type Siding is Bowed or Wavy

FH 3.9: Exterior Door is Warped

Performance

Doors shall not warp to the extent that they become inoperable or cease to be weather resistant. Doors between a home and an attached garage must be maintained to be gas-proof.

Warranty

One-Year - Work and Materials. Two-Year - Ontario Building Code Health & Safety Violation for doors requiring gas-proofing. • Damage resulting from improper maintenance or alterations, deletions or additions made by the homeowner is not covered by the statutory warranty.

Action

Doors not meeting the acceptable performance shall be replaced.

Remarks

Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Exterior doors can warp to some degree due to temperature differential between inside and outside surfaces. Garage doors between the garage space and the outdoors are not required to be weatherstripped. See Also: 3.13 EXTERIOR DOOR STICKS 3.14 EXTERIOR DOOR WILL NOT CLOSE COMPLETELY 3.15 PLASTIC MOULDING ON EXTERIOR DOOR IS DEFORMED 3.17 EXTERIOR DOOR IS CROOKED IN THE FRAME

Article number
3.9
Article type
Freehold
Warranty years
One Year
Two Year
Article title
Exterior Door is Warped

FH 3.8: Condensation Forming Between Insulating (Factory Sealed) Glass Unit

Performance

Insulating glass units shall be free from condensation between the panes.

Warranty

One-Year - Work and Materials

Action

Insulating glass units with condensation between the panes shall be replaced.

Remarks

Condensation between panes indicates the airtight seal around the edge of the glass is broken. An extended warranty may be available through the window manufacturer. See Also: 3.7 WINDOW UNIT LEAKS DURING RAIN 8.5 CONDENSATION AND/OR FROST ON WINDOWS

Article number
3.8
Article type
Freehold
Warranty years
One Year
Article title
Condensation Forming Between Insulating (Factory Sealed) Glass Unit

FH 3.7: Window Unit Leaks During Rain

Performance
Windows, when properly closed, shall not allow water penetration under conditions for which they were designed.
Warranty
One-Year - Work and Materials. Two-Year - Building Envelope Water Penetration . • Damage caused by improper maintenance or an act of God is excluded from the statutory warranty.
Action
Defective windows that leak shall be repaired or replaced.
Remarks
The homeowner must ensure operable windows are properly closed, weatherstripping and caulking is maintained and drain ports are not obstructed. The window manufacturer may provide extended warranty coverage. For window water penetration, see specifications in CAN/CSA-A440-M, “Windows”. See Appendix A5 ”How to Conduct a Water Test” for more information. See Also: 3.8 CONDENSATION FORMING BETWEEN INSULATING (FACTORY SEALED) GLASS UNIT 4.19 WATER LEAKAGE AT DOORS OR WINDOWS OR AT THE TOP OF THE FOUNDATION 8.5 CONDENSATION AND/OR FROST ON WINDOWS Appendix A5 “How to Conduct a Water Test”
Article number
3.7
Article type
Freehold
Warranty years
One Year
Two Year
Article title
Window Unit Leaks During Rain

FH 3.6: Glass is Cracked

Performance
Windows shall be installed so that the glass does not crack due to unusual stress caused by movement or settlement of the building frame.
Warranty
One-Year - Work and Materials. · Damage resulting from normal wear and tear is not covered by the statutory warranty.
Action
Windows with glass showing stress cracks shall be repaired.
Remarks
Stress cracks occur across corners of glass as a result of pressure being applied to the edge of the glass. If there is evidence of an impact, and the condition was not recorded on the PDI Form, it will be difficult to establish that the damage was caused by the builder. See Also: 3.4 WINDOW GLASS AND/OR SCREEN IS DAMAGED 3.5 GLASS IS SCRATCHED 3.8 CONDENSATION FORMING BETWEEN INSULATING (FACTORY SEALED) UNITS 8.5 CONDENSATION AND/OR FROST ON WINDOWS
Article number
3.6
Article type
Freehold
Warranty years
One Year
Article title
Glass is Cracked

Need assistance from Tarion?