Skip to main content

FH 9.3: Gypsum Wallboard Corners are uneven

Performance
Gypsum wallboard corners shall appear generally even and uniform when viewed under normal lighting conditions from a normal viewing position.
Warranty
One-Year - Work and Materials
Action
Joints not meeting the condition shall be repaired.
Remarks
Minor waviness may be more apparent in corners that are not right-angled and is acceptable. See Also: 3.1 WALL IS OUT OF PLUMB 3.2 WALL IS BOWED
Article number
9.3
Article type
Freehold
Warranty years
One Year
Article title
Gypsum Wallboard Corners are uneven

FH 9.8: Finished Surface Is Rough

Performance
Surfaces that are touched during normal use shall be uniformly smooth. Surfaces not touched during normal use shall appear smooth when viewed without magnification, from a minimum distance of 1,500 mm under normal lighting conditions and from a normal viewing position.
Warranty
One-Year - Work and Materials
Action
Surfaces not meeting the acceptable condition shall be made smooth and refinished.
Remarks
The open grain in some wood surfaces tends to show a rough appearance yet feel smooth; this is a natural property of wood and is acceptable. See Also: 9.7 FINISH OF PAINTED GYPSUM WALLBOARD (DRYWALL) VARIES
Article number
9.8
Article type
Freehold
Warranty years
One Year
Article title
Finished Surface Is Rough

FH 9.7: Finish of Painted Gypsum Wallboard (Drywall Varies)

Performance

Variations in the surface texture of finished gypsum wallboard (drywall) are normal.

Warranty

None

Action

None

Remarks

Wall and ceiling surfaces of gypsum wallboard consist of paper and joint compound. These materials accept paint finishes differently. Variations in texture of the final paint finish in the area of joints and fasteners may result and are normal. See Also: 9.2 CEILING TEXTURE IS UNEVENLY APPLIED 9.8 FINISHED SURFACE IS ROUGH

Article number
9.7
Article type
Freehold
Article title
Finish of Painted Gypsum Wallboard (Drywall Varies)

FH 8.2: Exterior Air Infiltration Through Windows and Doors

Performance

Windows and doors shall meet the rating for weather tightness required by the Building Code.

Warranty

One-Year - Work and Materials

Action

Ensure the window or door has been tested to meet the required weather tightness rating. Adjust weather stripping and/or hardware to reduce air leakage by ensuring positive contact along the weather seal.

Remarks

`

Article number
8.2
Article type
Freehold
Warranty years
One Year
Article title
Exterior Air Infiltration Through Windows and Doors

FH 9.6: Drywall Surface Blemishes including Nail/Screw Pops, Blisters In Taped Joints, Trowel Marks, Excess Joint Compound And Dents Or Gouges

Performance

Interior finished drywall (excluding garages and unfinished areas) shall be free from damage (dents and gouges) at the time of the PDI and be installed according to the Building Code. Blemishes readily noticeable when viewed under normal lighting conditions from a normal viewing position 1,800 mm perpendicular distance from the wall surface are unacceptable.

Warranty

One-Year - Work and Materials. · Nail pops resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. · Damaged areas of drywall not recorded on the PDI Form are excluded from the statutory warranty unless the homeowner is able to establish that the damage was caused by the builder.

Action

Only warranted drywall surface blemishes shall be repaired and refinished to match original builder-applied finish as closely as possible.

Remarks

Identify any damaged drywall surfaces (dents and gouges) on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Surface blemishes in drywall are not unusual at joints and at corners. The repair of surface blemishes resulting from normal shrinkage is at the builder’s discretion and sanding and repainting is not required. Builder’s specific policies with respect to drywall repairs will vary. Often these repairs are best left until the framing has settled. See Also: 9.4 CRACKS IN INTERIOR WALL AND CEILING SURFACES 9.5 CEILING/WALL JOINT SEPARATION COMMONLY REFERRED TO AS “TRUSS UPLIFT”

Article number
9.6
Article type
Freehold
Warranty years
One Year
Article title
Drywall Surface Blemishes including Nail/Screw Pops, Blisters In Taped Joints, Trowel Marks, Excess Joint Compound And Dents Or Gouges

FH 8.1: Draft Felt at Electrical Outlet

Performance

Electrical boxes on exterior walls that penetrate the air barrier system shall be installed to prevent air infiltration.

Warranty

One-Year - Work and Materials

Action

Electrical boxes not meeting the acceptable condition shall be repaired.

Remarks

Some drafts may occur around electrical outlets or receptacles on exterior walls, particularly when it is cold or windy. Convection air movement may simulate draft conditions. See Also: 8.7 INSUFFICIENT INSULATION

Article number
8.1
Article type
Freehold
Warranty years
One Year
Article title
Draft Felt at Electrical Outlet

FH 9.4: Cracks in Interior Wall and Ceiling Surfaces

Performance
Interior drywall shall be installed to minimize cracking of joints, corners and corner beads.
Warranty
One-Year - Work and Materials. · Cracks resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty.
Action
Only warranted cracks shall be repaired and refinished to match original builder-applied finish as closely as possible.
Remarks
Cracks are not unusual in drywall compound at joints, particularly at corners. Most cracks are a result of normal shrinkage and are generally not warranted. The repair of normal shrinkage cracks is at the builder’s discretion and sanding and repainting is not required. Builder’s specific policies with respect to drywall repair will vary. These repairs are best left until the framing has settled. See Also: 9.5 CEILING/WALL JOINT SEPARATION COMMONLY REFERRED TO AS “TRUSS UPLIFT”
Article number
9.4
Article type
Freehold
Warranty years
One Year
Article title
Cracks in Interior Wall and Ceiling Surfaces

FH 8.6: Condensation on Interior Ductwork And Air Handling Equipment

Performance

Condensation may occur on indoor ductwork and air handling equipment.

Warranty

None. · Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty.

Action

None

Remarks

This condition may occur in the summer when air conditioning equipment is operating or in winter when ducts are chilled by incoming outdoor air. For example, condensation may occur on range hood exhaust ducts during cold outdoor temperatures.

Article number
8.6
Article type
Freehold
Article title
Condensation on Interior Ductwork And Air Handling Equipment

FH 8.4: Condensation In Attic Space

Performance
Condensation may occur in attics but these occurrences should be infrequent and without any adverse effect on the building.
Warranty
Two-Year - Ontario Building Code Health & Safety Violations. · Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty.
Action
Adequate ventilation equipment shall be installed in accordance with the Building Code.
Remarks
Attic spaces shall be ventilated in accordance with the Building Code. Condensation in attics may indicate either a lack of ventilation through the attic or a source of moisture within the attic space. See Also: 8.7 INSUFFICIENT INSULATION
Article number
8.4
Article type
Freehold
Warranty years
Two Year
Article title
Condensation In Attic Space

FH 8.5: Condensation And/Or Frost On Windows

Performance
Condensation may occur on interior window surfaces and is not covered under warranty.
Warranty
None.
Action
None
Remarks
Condensation occurs when water vapour in indoor air comes in contact with cool surfaces such as window glass. Condensation on interior window surfaces is common during cold seasons. When outdoor temperatures are well below freezing, ice may form at the bottom of windows. Condensation is not water penetration.It is important for homeowners to maintain proper humidity levels within the home. Condensation forming on windows is a common condition even when humidity levels are properly maintained. Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty.Interior air moving over the windows can help control condensation. Heavy draperies or window coverings that cover windows, and blocked heat diffusers, can prevent this from happening. Running the ventilation fan or your heat recovery (HRV) or energy recovery ventilator (ERV) and furnace fan continuously during winter months in conjunction with the principal exhaust fan (or running the HRV/ERV and furnace fan continuously where the HRV/ERV replaces the principal fan) can also help reduce condensation on windows.NotesThis Article, as revised, applies to all conciliations after January 1, 2019.See Also:3.4 WINDOW GLASS AND/OR SCREEN IS DAMAGED3.5 GLASS IS SCRATCHED 3.6 GLASS IS CRACKED3.6 GLASS IS CRACKED3.7 WINDOW UNIT LEAKS DURING RAIN3.8 CONDENSATION FORMING BETWEEN INSULATING (FACTORY SEALED) GLASS UNIT
Article number
8.5
Article type
Freehold
Article title
Condensation And/Or Frost On Windows

Need assistance from Tarion?

If you have questions about your home or the warranty, please Contact Us