Skip to main content

CE 5.1: Floor Is Uneven

Home type
Performance

Applied finished flooring shall be installed without visible ridges or depressions. Where visible ridges or depressions occur, the variation shall not exceed plus/minus 6 mm from the specified plane.

Warranty

One-Year - Work and Materials. Ridges and depressions caused by normal shrinkage of materials are excluded from the statutory warranty.

Action

Visible ridges or depressions exceeding the acceptable condition shall be repaired.

Remarks

The homeowner must maintain finished flooring in accordance with manufacturer’s recommendations and prevent the accumulation of water on flooring.

Article number
5.1
Article type
Common Element
Warranty years
One Year
Article title
Floor Is Uneven

CE 4.12: Fire Detection - Ground Faults/Trouble Indication

Home type
Performance
A fire alarm system should not indicate faults or trouble within the warranty period.
Warranty
One-Year - Work and Materials. Two-Year - Ontario Building Code Health and Safety Violation
Action
Conditions causing trouble indication shall be repaired.
Article number
4.12
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Fire Detection - Ground Faults/Trouble Indication

CE 4.11: Concrete Block Wall In a Fire Seperation Is Cracked

Home type
Performance
Cracks in a concrete block wall that acts as a fire separation are not permitted.
Warranty
One-Year – Work and Materials. Two-Year – Health and Safety
Action
Cracks shall be repaired to maintain the fire separation integrity.
Article number
4.11
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Concrete Block Wall In a Fire Seperation Is Cracked

CE 4.10: Missing Fire Dampers

Home type
Performance

Where fire dampers are required by the Ontario Building Code or the design, they shall be provided and properly set.

Warranty

One-Year - Work and Materials. Two – Year – Ontario Building Code Health and Safety Violations

Action

Conditions not meeting the acceptable performance standard shall be repaired

Article number
4.10
Article type
Common Element
Warranty years
One Year
Article title
Missing Fire Dampers

CE 2.3: Exposed Balcony Concrete Finishes Have Formwork Ridges

Performance

There should be no formwork ridges on exposed balcony concrete surfaces.

Warranty

One-Year - Work and Materials

Action

Formwork ridges shall be smoothed.

Remarks

When the removal of marks or imperfections from the concrete forms is carried out, it must be carried out in a good workmanlike manner, and should not degrade the overall aesthetic appearance that was intended.

Article number
2.3
Article type
Common Element
Warranty years
One Year
Article title
Exposed Balcony Concrete Finishes Have Formwork Ridges

CE 2.20: Condensation On Window Systems

Performance

Condensation on the interior surfaces of window systems is not warranted unless it is clearly determined to result from workmanship related to the construction or non-compliance with the Ontario Building Code, the design or the manufacturer’s installation guidelines

Warranty

One-Year -Work and Materials. Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation or proper operation of moisture-producing devices such as humidifiers is excluded from warranty.

Action

Windows not meeting the acceptable performance criteria shall be repaired.

Remarks

Condensation can be a result of lifestyle. Condensation occurs when water vapour in indoor air contacts cool surfaces such as window glass. Condensation on interior window surfaces is common during cold seasons. When outdoor temperatures are well below freezing, ice may form on the window. Since it is important for homeowners to maintain proper humidity levels within the home to prevent damage to other components such as hardwood flooring and for physical health, some condensation on windows may be expected. Indoor humidity levels may be controlled by de-humidification, ventilation or air conditioning. Interior air moving over the windows can help control condensation. Heavy draperies or window coverings that cover windows and blocked heat diffusers can prevent this from happening. Running the ventilation fan continuously can also help to control condensation on windows.

Article number
2.20
Article type
Common Element
Warranty years
One Year
Article title
Condensation On Window Systems

CE 10.9: Barrier-Free Ramp Width Between Handrails Is Not Wide Enough

Home type
Performance

Ramps located in a barrier-free path of travel are required to have a minimum between handrails per Ontario Building Code.

Warranty

One-Year – Work and Materials. Two-Year - Ontario Building Code Health and Safety Violation

Action

Ramps not meeting the Acceptable Performance shall be repaired.

Article number
10.9
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Barrier-Free Ramp Width Between Handrails Is Not Wide Enough

CE 10.8: Glass Doors Not Clearly Identified

Home type
Performance
A door in a barrier-free path of travel consisting of a sheet of glass is required to be marked with an opaque strip (attributes defined in the Ontario Building Code) so that it is readily apparent.
Warranty
One-Year – Work and Materials. Two-Year - Ontario Building Code Health and Safety Violation
Action
Code compliant identification is required to be provided.
Article number
10.8
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Glass Doors Not Clearly Identified

CE 10.7: Vision Panels In Doors In a Barrier-Free Path Of Travel Are Not Sized Or Located Properly

Home type
Performance
Where a vision panel is provided in a door in a barrier-free path of travel, it must comply with the location and dimensional requirements of the Ontario Building Code.
Warranty
One-Year – Work and Materials. Two-Year - Ontario Building Code Health and Safety Violation
Action
Visions panels not complying with the Acceptable Performance shall be repaired.
Remarks
Applies to all doors with vision panels and located in a barrier-free path of travel
Article number
10.7
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Vision Panels In Doors In a Barrier-Free Path Of Travel Are Not Sized Or Located Properly

CE 10.6: Doors Require Excessive Force To Open

Home type
Performance

The opening force required to open doors in barrier-free paths of travel must comply with Ontario Building Code.

Warranty

One-Year – Work and Materials. Two-Year - Ontario Building Code Health and Safety Violation

Action

Doors not complying with the acceptable performance shall be repaired.

Remarks

Door opening force does not apply to doors equipped with power door opening/closing devices. Regular maintenance of building systems (doors, air balance) is required to ensure that the requirements of the code are maintained.

Article number
10.6
Article type
Common Element
Warranty years
One Year
Two Year
Article title
Doors Require Excessive Force To Open

Need assistance from Tarion?