FH 5.5: Inadequate Attic Ventilation
Article type: FreeholdAttics shall be ventilated in accordance with the Building Code.
-
FH 5.6: Ice Buildup on the Roof
Article type: FreeholdRoofs and attics shall be constructed with sufficient ventilation (if designed to include ventilation), air sealing and thermal insulation to minimize ice buildup on roof surfaces.
-
FH 5.7: Roof Shingles Have Blown Off
Article type: FreeholdRoof shingles shall be installed according to the Building Code and the manufacturer’s specifications.
-
FH 5.8: Tabs on Asphalt Shingles Are Not Lined Up
Article type: FreeholdShingles shall be installed to provide a generally uniform pattern when viewed from a normal viewing position on the ground from any given location.
-
FH 5.9: Asphalt Shingles Not Sealed
Article type: FreeholdAsphalt shingles and self-sealing asphalt shingles shall be secured according to the Building Code.
-
FH 7.1: Fuses Blow or Circuit Breakers Trip
Article type: FreeholdElectrical circuits shall be installed in accordance with the Ontario Electrical Safety Code.
-
FH 7.2: Ground-Fault Circuit Interrupter (GFCI) Trips Frequently
Article type: FreeholdGFCIs shall be installed in accordance with the Ontario Electrical Safety Code. -
FH 7.3: Electrical Outlets or Switches Don't Work
Article type: FreeholdElectrical outlets and switches shall be installed in accordance with manufacturer’s specifications and the Ontario Electrical Safety Code.
-
FH 7.4: Electrical Fixture Doesn't Work
Article type: FreeholdElectrical fixtures supplied and installed by the builder shall be installed in accordance with the manufacturer’s specifications and the Ontario Electrical Safety Code.
-
FH 7.5: Receptacle/Switch Cover Plate is Not Flush with the Wall
Article type: FreeholdElectrical receptacles/switches shall be installed so that the cover plate sits generally flush with the adjacent wall surface.
-
FH 7.6: Exhaust Fan Duct Terminates in Attic or Crawl Space
Article type: FreeholdExhaust fans shall be ducted to the exterior in accordance with the Building Code.
-
FH 7.7: Interior Light Fixture Tarnished
Article type: FreeholdInterior light fixtures supplied and installed by the builder shall not tarnish.
-
FH 7.8: Ceiling Fan Vibrates and Is Noisy
Article type: FreeholdCeiling fans shall be installed and maintained in accordance with the manufacturer’s installation instructions. -
FH 14.11 : Tree Stumps Have Been Left on the Property
Article type: FreeholdWhere the builder is responsible for final grading under the contract and trees have been cut down as part of the construction process, stumps shall be removed. -
FH 14.12: Water Ponding in Surface Grading of the Site
Article type: FreeholdThe site shall be graded so that water does not generally accumulate adjacent to the building. Backfill against a foundation shall be graded to prevent drainage towards the building after settling. Where no grade is specified for a slope, a minimum gradient of 2% is considered acceptable; sodded or graveled areas may have a minimum gradient of 1%.