FH 8.7: Insufficient Insulation
Article type: FreeholdPerformance/Condition: Insulation shall be installed in accordance with the Building Code.
-
FH 8.3: Kitchen Or Bath Fans Allow Cold Air Infiltration Or Drafts
Article type: FreeholdKitchen and bath exhaust fans shall be installed with back draft dampers as per manufacturer’s specifications.
-
FH 9.15: Mildew or Fungus is visible on Interior Surfaces
Article type: FreeholdInterior surfaces shall be free of visible mildew and fungus at the time of the PDI. This condition is warranted where there is a demonstrated Building Code violation or defect in work or material supplied by the builder.
-
FH 9.9: Paint Finish is Unacceptable
Article type: FreeholdA properly painted surface shall be produced on every exposed surface where a painted finish is specified. A properly painted surface shall be assessed by viewing, without magnification, from a minimum perpendicular distance of 1,500 mm under normal lighting conditions and from a normal viewing position.
-
FH 9.11: Paint is Splattered on Surface not intended to be painted
Article type: FreeholdInterior surfaces not intended to be painted shall not have paint splatters when viewed under normal lighting conditions from a normal viewing position.
-
FH 9.13: Patterns In Wallcovering Are Mismatched At The Edges
Article type: FreeholdWallcoverings shall be installed to achieve a generally uniform appearance when viewed under normal lighting conditions and from a normal viewing position, within the manufacturer’s tolerances. -
FH 9.12: Wallcovering is Peeling
Article type: FreeholdWallcoverings shall not be peeling at the time of the PDI. This condition is warranted only where a defect in work or material is demonstrated. -
FH 9.14: Water Penetration Behind Ceramic Tile and Bathtub or Shower Enclosure
Article type: FreeholdJoints between ceramic tiles and adjacent surfaces shall prevent water penetration.
-
FH 8.10: Inadequate Cooling
Article type: FreeholdCooling systems shall be capable of maintaining an indoor air temperature of 24°C at the design temperature for the geographical location.
-
FH 6.1: Inadequate Water Supply
Article type: FreeholdWater supply from private water sources (e.g. wells) may fluctuate from time to time. Water supply from municipal water sources may vary with the supplied pressure.
-
FH 6.2: The Domestic Water Supply System does not Deliver Water
Article type: FreeholdThe domestic water supply system supplied and installed by the builder shall be capable of delivering water from a municipal or private (well) source throughout the home.
-
FH 6.3: Pipes are leaking
Article type: FreeholdDomestic water supply and drainpipes shall not leak. -
FH 6.4: Faucet or fixture is leaking
Article type: FreeholdFaucets or plumbing fixtures shall not leak, drip or run on when fully closed or shut off.
-
FH 6.5: Plumbing pipes are frozen and/or burst
Article type: FreeholdPlumbing pipes shall be protected from freezing in accordance with the Building Code.
-
FH 6.6: Bathtub or shower leaks
Article type: FreeholdBathtubs and showers shall be installed in accordance with manufacturer’s specifications so they do not leak.