CE 8.5: Electrical Equipment Missing Sprinkler Shields
Article type: Common ElementWhere electrical equipment is installed in a sprinklered space, shields must be installed to protect the electrical equipment from the water in the event that the sprinklers are triggered. -
CE 8.6: Fuel Storage And Delivery System Non-Compliant
Article type: Common ElementFuel storage tanks and equipment shall comply with TSSA requirements in force at the time of condominium registration. -
CE 8.7: Defects In Generator And Related Equipment
Article type: Common ElementGenerators and related storage tanks and equipment shall comply with TSSA requirements in force at the time of condominium registration. -
CE 9.6: Landscaping Not Sloped Away From Foundation Or Building Walls
Article type: Common ElementLandscaping shall be graded to prevent drainage towards the foundation or building walls.
-
CE 9.7: Exterior Handrail/Guard/Fence Finish Deteriorated
Article type: Common ElementHandrail, guard and fence finishes shall remain intact for the warranty period.
-
CE 9.8: Retaining Wall Shifting
Article type: Common ElementRetaining walls must remain in place without shifting in a manner which affects performance.
-
CE 9.9: Leakage Through Concrete Retaining Walls and Concrete Planter Walls
Article type: Common ElementConcrete retaining walls or planter walls shall not display water seepage unless the walls are designed to accommodate seepage without causing damage to the exposed finishes.
-
CE 4.4: Gaps Around Suite Entry Doors
Article type: Common ElementSuite doors located in corridors shall be installed to meet with the Ontario Building Code, referenced NFPA standards and the design. -
CE 4.5: Unsealed Form-Tie Holes
Article type: Common ElementForm-tie holes in demising and fire-rated partitions shall be sealed.
-
CE 4.6: Fire Hose Cabinet Doors Block Doorways Or Are Blocked
Article type: Common ElementFire hose cabinets are required to be installed in conformance with the Ontario Building Code. However, fire hose cabinet doors are not to obstruct a means of egress when fully open, nor can they be located where they are likely to be obstructed. -
CE 4.7: Sprinkler Head Too Close To Slab
Article type: Common ElementUpright sprinkler head deflectors are required to be located a minimum of 25 mm and a maximum of 300 mm below the slab per NFPA standards referenced in the Code. -
CE 4.8: Sprinkler Coverage Inadequate In Locker Room
Article type: Common ElementSprinkler coverage shall not be blocked by partitions (partition walls and framing members) constructed around lockers. Sprinklers are required to be located in such a manner that obstructions do not impede the sprinkler discharge pattern development. -
CE 4.9: Self-Closing Devices Not Operating Effectively
Article type: Common ElementSelf-closing devices shall be able to close and latch the door automatically and shall comply with the requirements of the Ontario Building Code.
-
FH 14.6: Water Accumulates on Garage Floor
Article type: FreeholdProvided garage floors are sloped to drain to the exterior, localized variations in the surface ofthe floor may impede immediate drainage and are acceptable. -
FH 14.7 : Asphalt or Concrete Driveway has Cracked
Article type: FreeholdCracks are acceptable if caused by factors other than a defect in work or materials provided by the builder.