Skip to main content
Condition
FH 1.5: Concrete Floor Slab-on-Ground Has settled in a Finished area
Article Type
Freehold
Article Number
1.5
Warranty Year(s)
One Year
Performance
At the perimeter of rooms, concrete floor slabs shall not settle more than 12 mm from their original position.
Warranty
One-Year - Work and Materials
Action
Slabs that settle more than the acceptable condition shall be repaired.
Remarks
None