- Condition
- CE 1.2: Leakage Through Buried Roof Slab - Not Exposed To Chlorides
- Article Type
- Common Element
- Article Number
- 1.2
- Warranty Year(s)
- One Year
- Performance
Buried roof slabs shall be designed and constructed to prevent water penetration and leakage in accordance with the Ontario Building Code and the design.
- Warranty
One-Year – Work and Materials. Two-Year - Building Envelope Water Penetration
- Action
The waterproofing system, not meeting acceptable performance, shall be repaired.
- Condition
- CE 1.4: Leakage Through Basement Or Foundation Walls Or Slabs-On-Grade
- Article Type
- Common Element
- Article Number
- 1.4
- Performance
- Basements/foundation walls and slabs-on-grade shall allow no water penetration/leaks
- Warranty
- Two- Year – Basement or Foundation Water Penetration. Water leakage resulting from improper maintenance, exterior grade alterations made by the homeowner, an act of God or failure of municipal services or other utilities is excluded from the statutory warranty. Secondary damage to property or any personal injury resulting from the water penetration is also excluded from the statutory warranty.
- Action
- Water penetration through the basement or foundation walls or slabs-on-grade shall be repaired.
- Condition
- CE 1.5: Cracks In Conventionally Reinforced Concrete Elements
- Article Type
- Common Element
- Article Number
- 1.5
- Performance
Cracks resulting from normal shrinkage or cracks anticipated in the design are acceptable.
- Warranty
One -Year – Work and Materials
- Action
No action required.
- Condition
- CE 1.6: Exposed Structural Floor Is Out Of Level
- Article Type
- Common Element
- Article Number
- 1.6
- Warranty Year(s)
- One Year
- Performance
- Where a floor structure is intended to be level, the floor shall appear level when viewed from a normal viewing position. Where a floor structure has some slope it shall meet the requirements of the design. Where no design tolerances are specified, a maximum tolerance ratio of 25 mm in 3600 mm applies. Abrupt changes in the surface which create a tripping hazard are not acceptable.
- Warranty
- One-Year - Work and Materials. Ridges and depressions caused by normal shrinkage of materials are excluded from the statutory warranty.
- Action
- Floors with slope beyond the acceptable performance shall have finishes removed, the floor leveled and the finishes reinstated. Visible ridges or depressions exceeding the acceptable condition shall be repaired.
- Condition
- CE 1.7: Concrete Surface Scaling
- Article Type
- Common Element
- Article Number
- 1.7
- Warranty Year(s)
- One Year
- Performance
Concrete surfaces shall not disintegrate to the extent that the aggregate is exposed under normal use.
- Warranty
One-Year – Work and Materials
- Action
The concrete surface shall be repaired.
- Condition
- CE 1.8: Ponding Water on Surfaces
- Article Type
- Common Element
- Article Number
- 1.8
- Warranty Year(s)
- One Year
- Performance
Surfaces which are sloped for drainage may have minor variations in the surface may impede immediate drainage and are acceptable. Standing water with a depth of less than 6 mm and in a pond less than 1m in breadth 24 hours after wetting is acceptable unless it is located in any area of the surface which cannot be easily avoided during normal pedestrian use (examples would be the area immediately beside a doorway or where an individual steps when exiting their parked car or similar) in which case any ponding remaining after 24 hours is not acceptable.
- Warranty
One-Year – Work and Materials
- Action
Ponding in excess of acceptable performance shall be repaired.
Repair shall prevent water from penetrating into the building Care must be taken to prevent damage to waterproof membrane during required maintenance activities to exposed surface above the buried roof. The Ontario Building Code references CSA S413, Item 4 which requires protection against leakage. Expansion joints shall be repaired to accommodate movement Exposed to chlorides refers to slabs which are exposed to de-icing chemicals. This typically applies to slabs located below driveways, parking, and walkways. Slabs located below sod or gardens would be considered “not exposed to chlorides”.
Shrinkage cracks and cracks anticipated in the design do not require repair. Review by a structural consultant may be required to confirm acceptability of cracking.
Some architectural finishes deliberately expose aggregate; this would not be considered scaling. Scaling of exterior concrete surfaces including concrete porches, walkways, garage floor slabs, steps (including precast), etc., most often results from salts and de-icers being applied to the concrete surface, e.g. either intentionally for ice melting or unintentionally from road slush deposits. Cleaning salt deposits off concrete surfaces is normal home maintenance. Feathering the edges of patch materials, which creates a weak edge or installing the patch material too thinly should be avoided. Manufacturer’s installation guidelines should be followed. Concrete is generally not susceptible to scaling in a one year timeframe due to exposure to salt. Deep deterioration that exposes reinforcing would not be considered scaling but rather a structural degradation. This may merit further investigation. Mechanical abrasion caused by the actions of the homeowner is not warranted.
It is normal for water to accumulate on surfaces immediately after a wetting event. Only water which remains after 24 hours is considered ponding.