Skip to main content
Image
Condition
CE 2.4: Corrosion Of Coated Metal Elements
Article Type
Common Element
Article Number
2.4
Warranty Year(s)
One Year
Performance

Protective coatings shall remain intact and effective for the warranty period. Protective coatings shall remain free of corrosion.

Warranty

One-Year - Work and Materials

Action

Corroded materials, corrosion shall be removed and the substrate refinished with appropriate protective coating.

Condition
CE 2.5: Defective Caulking
Article Type
Common Element
Article Number
2.5
Warranty Year(s)
One Year
Performance

Caulking should be installed in accordance with manufacturer’s specifications. Caulking shall remain intact without de-bonding, cracking/splitting or showing other signs of premature strain within the warranty period. Profiling of caulking should accommodate anticipated movement at the sealed joint. Caulking must cure as anticipated in the manufacturer’s specifications. All joints shown in the design to be caulked shall be caulked.

Warranty

One-Year - Work and Materials. One-Year – Ontario Building Code Violation. Two-Year – Cladding Detachment, Displacement or Deterioration. Damage resulting from improper maintenance is not covered by the statutory warranty

Action

Caulking which does not achieve the specified performance requirements shall be repaired.

Condition
CE 2.16: Water Leak Through Building Envelope (Exterior Closure)
Article Type
Common Element
Article Number
2.16
Performance

The building envelope/exterior closure shall be constructed to prevent water entry into the interior of the building.

Warranty

One - Year – Work and Materials. One - Year – Ontario Building Code Violations. Two -Year – Building Envelope Water Penetration. Damage resulting from normal wear and tear, improper maintenance or additions, alterations and deletions made by the homeowner is not covered by the statutory warranty.

Action

Building envelopes/exterior closures not meeting the acceptable condition shall be repaired.

Condition
CE 2.17: Water Leak Through Windows or Doors
Article Type
Common Element
Article Number
2.17
Performance

The building envelope openings in exterior walls such as windows and doors, and junctions between cladding materials, shall not allow water penetration.

Warranty

One - Year – Ontario Building Code Violations. Two -Year – Building Envelope Water Penetration. Damage resulting from normal wear and tear, improper maintenance or additions, alterations and deletions made by the homeowner is not covered by the statutory warranty.

Action

Defects resulting in water penetration through the envelope, around windows and doors shall be repaired.

Condition
CE 2.18: Construction Material Splatters and Stains
Article Type
Common Element
Article Number
2.18
Performance

The building shall not have splatters and/or stains relating to construction materials which detract from the appearance of the building when viewed from a distance of 6m. For balconies, terraces etc where a 6m viewing distance is impractical then the condition shall be assessed from a normal viewing position.

Warranty

One – year – Work and Materials

Action

Conditions not meeting the acceptable condition shall be repaired.

Remarks

This item is not intended to address corrosion related to chips or other post-installation damage, but rather material failure of the paint finish. Components which are specified to be shop primed will be expected to corrode, and corrosion of these elements is not warranted.

Remarks

Leakage into the interior refers both to leakage into occupied spaces and also to leakage into the concealed portions of a wall system that is intended to be face-sealed. The building envelope/exterior closure includes the elements which separate the interior conditioned space from the exterior and includes cladding, windows, doors, vents, louvers, grilles etc. Roofing is covered separately. Joints and cracks in exterior wall surfaces and around openings shall be properly sealed to prevent the entry of water unless otherwise considered by the design. Repairs cannot alter the design intent of the cladding system. For example, leaks in a rain-screen system cannot be face-sealed.

Remarks

Some minor splatters in areas of the building which are not routinely occupied (e.g. mechanical penthouse) and which are not visible from routinely occupied areas may be considered acceptable.

Need assistance from Tarion?

If you have questions about your home or the warranty, please Contact Us

Back