Skip to main content
Condition
FH 1.9: Exposed Cast-In-Place Concrete Foundation Wall Has Holes In Surface
Article Type
Freehold
Article Number
1.9
Warranty Year(s)
One Year
Performance

The exterior portion of foundation walls exposed to view above grade shall have no holes (including “honeycombing”) larger than 50 mm in diameter or 25 mm deep.

Warranty

One-Year – Work and Materials

Action

Walls with holes exceeding the acceptable condition shall be repaired.

Remarks

It is impossible to completely eliminate all surface voids. At the builder’s discretion a brush coat may be applied. The colour and texture of a repaired area may not match the surrounding concrete. See item 1.15 “Brush coating on above grade poured concrete foundation wall is falling off”