Skip to main content
Condition
FH 10.24: Gaps Between Baseboard Trim and Finished Floor Surface
Article Type
Freehold
Article Number
10.24
Warranty Year(s)
One Year
Performance

Where baseboard trim abuts finished flooring, gaps in plain view that are in excess of 3 mm are not acceptable (except at transitions between different finished floor materials).

Warranty

One-Year - Work and Materials Minor gaps caused by normal shrinkage of materials due to drying after construction are excluded from the statutory warranty.

Action

Baseboard installations not meeting the acceptable condition shall be repaired.

Remarks

Surface variations in natural or manufactured stone tiles are considered to be desirable characteristics of the product and may affect how tightly the baseboard trim can be fitted to it. In addition, minor irregularities in flooring surfaces are also considered to be normal. In areas where hard surface finished flooring is installed, an additional trim molding like a quarter round or shoe molding, is an acceptable practice to conceal minor gaps between baseboards and the finished flooring.See Also10.11 GAPS EXIST BETWEEN STAIR PARTS10.17 INTERIOR TRIM IS SPLIT10.18 HAMMER MARKS ARE VISIBLE ON TRIM Notes This article, as revised, applies to conciliations after June 1, 2019.Words in italics are defined in the “TERMINOLOGY” section.