CE 6.10: Oil Leaks, Grease Fitting, Bearing Seals Shall Be Free Of Leaks Or Defect
Article Type
Common Element
Article Number
6.10
Warranty Year(s)
One Year
Performance
Elevators equipped with oil fitting, packing, valves, pumps, reservoir tank (hydraulic elevators), or bearings (sealed or unsealed), deflector sheaves, sprockets, oil buffers, etc. shall be free of oil leaks or grease escaping or leaking from the fittings.
Warranty
One-Year - Work and Materials
Action
Equipment not meeting the Acceptable Performance/Condition shall be repaired.
Remarks
Ensuring that all components are operating as intended (leak free) is important for the longevity and proper operating of the components. Leaking bearings can result in a premature failure and seizing of the component. Leaking cylinders or coupling can be the result of excessive heat or component failure or could be the result of construction dust entering the packing.
Need assistance from Tarion?