Skip to main content
Condition
CE 2.13: Cracks in Exterior Stucco Wall Surfaces
Article Type
Common Element
Article Number
2.13
Performance

Fine hairline cracks that do not negatively affect the performance of the stucco are acceptable.

Warranty

One - Year – Work and Materials. One - Year – Ontario Building Code Violations. Two -Year – Cladding Detachment, Displacement or Deterioration. Damage resulting from normal wear and tear, improper maintenance or additions, alterations and deletions made by the homeowner is not covered by the statutory warranty.

Action

Stucco finish not meeting the acceptable condition shall be repaired.

Remarks

Stucco refers to systems typically over 6mm thick incorporating Portland cement. Cracks may be acceptable from a performance perspective if the system is drained, but may not be acceptable from an aesthetic perspective depending on the location of the cracks. Some cracking in areas of the building which are not routinely occupied (mechanical penthouse for example) may be considered acceptable if it does not negatively impact performance (leakage resistance etc). The colour or texture of repaired areas shall match the existing as close as possible, and the patched area should not be readily apparent when viewed from a distance of 6 m under normal lighting conditions. Generally the cracks which are intended to be repaired will be visible from a distance of 6m however, in some instances; smaller cracks may negatively impact performance. The width of cracks will vary with temperature. Larger in cold weather, smaller in hot weather.

Need assistance from Tarion?

If you have questions about your home or the warranty, please Contact Us

Back